Advantage Controls Microtron Series B Pumps
The Series B come with standard rotary encoder switch to allow exact stroke speed setting of pumps, on/off indicator light, stroke indicator light and panel dust cover. Stroke length and speed are individually adjustable via knobs.
Series B metering pumps provide reliable, economical chemical addition for a wide variety of applications. Precise stroking speed is maintained with a digitally accurate speed adjustment. Metering accuracy is achieved with double ball guided checks. A rugged housing with control cover is suitable for outdoor installations. Available in outputs up to 45 GPD and 250 PSI with control options including:
- External Pace
- Dual Output
- Limit Timer
- External Stop
DRIVE SELECTIONS
The pump models that you can select from the first dropdown menu are:
- Model B145 = 45 GPD at 75 PSI
- Model B130 = 30 GPD at 110 PSI (Default Selection)
- Model B115 = 15 GPD at 110 PSI
- Model B217 = 17 GPD at 250 PSI
The control options that you can select from the second dropdown menu are:
- X = (Standard) Control (Default Selection)
- D = Dual Output 10-50 sph or 125 spm
- E = External Pace
- F = Hall Effect flow meter input (divides by 9)
- L = Limit Timer
The voltage options that you can select from the third dropdown menu are:
- 1 = (Standard) 120 Volt USA plug, 5.5’ long (Default Selection)
- 2 = 240 No plug
- 3 = 240 South American plug
- 4 = 12 Volt DC (60 PSI max; Output not affected)
- 5 = 240 Volt USA plug
- 6 = 240 Volt Korean plug / 60 cycle
- 7 = 240 Volt Australian plug
WET END SELECTIONS
The head and fitting options that you can select from the fourth dropdown menu are:
- K = Kynar (Default Selection)
- S = 316SS*
- M = Kynar Head w/ SS MNPT Valves*
- D = Kynar Degassing
* M and S options must have P connection code
The seat and O-ring options that you can select from the fifth dropdown menu are:
- V = Viton (Default Selection)
- F = Teflon
- H = Hypalon
The connection options that you can select from the sixth dropdown menu are:
- 1 = 3/8” Tubing for 75-200 psi (Default Selection)
- 2 = 1/4” Tubing for 250 psi
- K = Kynar suct / disch tubing
- P = 1/4” MNPT
- Q = 1/4” MNPT disch / 1/4” FNPT suc
- R = 1/4” FNPT
- U = 3/8” Black UV resistant
- V = Clear flex 3/8” suct tubing
The ball check options that you can select from the seventh dropdown menu are:
- C = Ceramic (Default Selection)
- D = Ceramic (single on discharge)
- S = Stainless
OTHER OPTIONS
We are thinking that the following is getting a little too exotic and complicated for auto selection and are best addressed as a custom order. You can select and contact us for pricing on up to three of the following:
- 4 = Blue Housing
- 5 = Green Housing
- 6 = Conformal Coating
- E = External Stop
- F2 = Paddlewheel Flow Meter, Kynar construction
- P ON/OFF Power Switch
- R = Remove Stroke Adjust
- S = 3-Function Valve (25 lbs load, anti-siphon & check)
If you need further customization than what you see here, Contact Us.
Chemical Compatibility
When building the liquid end portion of a pump model it is critical that the materials selected are compatible with the product to be pumped. Listed below are some common chemicals and recommended liquid end codes. Example: Sodium Hypochlorite (chlorine) A130X1-KVCV.
Chemical | Code |
ACETIC ACID, 5-10% | KHC |
ALUMINUM SULFATE ‘alum’ | KHC |
AMINES, 0 - 35% | KFC |
AMINES, > 40% | SFS |
AMMONIA, 10% | KHC |
BROMINE | KFC |
CALCIUM HYPOCHLORITE | KVC |
DBNPA | KFC |
ETHYLENE GLYCOL | KFC |
FERRIC CHLORIDE | KFC |
FERRIC SULFATE | KFC |
GLUTARALDEHYDE | KFC |
HYDROCHLORIC ACID, 0 - 37% | KFC |
HYDROGEN PEROXIDE, 0 - 30% | KVC |
INHIBITING PHOSPHONATES | KFC |
ISOTHIAZOLINE | KFC |
NITRIC ACID, 0 - 20% | KVC |
PHOSPHORIC ACID, 0 - 100% | KFC |
POTASSIUM CHLORIDE | KFC |
SODIUM BI-CARBONATE ‘soda ash’ | KFC |
SODIUM BI-SULFATE | KFC |
SODIUM BI-SULFITE | KFC |
SODIUM BROMIDE | KFC |
SODIUM CARBONATE | KFC |
SODIUM HYDROXIDE, ‘caustic’, 0 - 50% | KHC |
SODIUM HYPOCHLORITE | KVC |
SODIUM NITRATE | KFC |
SODIUM SILICATE | KHC |
SODIUM SULFATE | KHC |
SODIUM SULFIDE | KHC |
SULFURIC ACID, 10 - 75% | KFC |
SULFURIC ACID, 95 - 100% | KFC |
MicroTron Series B metering pumps provide reliable, economical chemical addition for a wide variety of applications. Precise stroking speed is maintained with a digitally accurate speed adjustment. Metering accuracy is achieved with double ball guided checks. A NEMA 4X style housing allows for outdoor installations. Series B pumps are available in outputs up to 55 GPD and 250 PSI. The manual stroke length and digital speed adjustment provides a wide turn down capability on all models.
Key Features: • Dual Output Adjustment • NEMA 4X Style Enclosure • Guided Double Ball Checks • Circuit Voltage Protection • Thermal Overload Protection • Priming / Degassing Valve • LED Indicating Lights • Splash Cover Over Controls
There are many other options available. Contact us with your unique requirements.
Prices for the Continental 48 states of the USA only.