Advantage Controls Micrtron RO Pumps
The Series R Controller/pump combination units come standard with a 1 x 16 backlit LCD readout, on/off light, stroke indicator light, 5 amp fuzed relay output, and panel dust cover. Stroke length is manually adjustable via knob, and speed is electronically programable up to 125 Strokes per Minute.
MicroTron Series R pumps combine chemical metering and a control relay output function in one simple unit.
The Model RO pump controller combination provides:
- ORP Control with alarm relay output.
Model R pumps may be ordered in the following configurations: • Conductivity Control • Conductivity Control with Feed Timer • Conductivity Control with Biocide Timer • Dual Pulse Timers • Dual 28-day Biocide Timers • Dual Sequential Percent Timers • pH Control • ORP Control
Key Features: • Microprocessor Controlled • Control Relay Output • NEMA 4X Style Enclosure • Splash Cover Over Controls • Guided Double Ball Checks • LED Indicating Lights • LCD Backlit Display • Widest Turn Down Capability • Thermal Overload Protection • Priming Valve Standard
DRIVE SELECTIONS
The pump models that you can select from the first dropdown menu are:
- Model RO30 - 30 GPD at 110 PSI
- Model RO15 - 15 GPD at 150 PSI
- Model RO17 - 17 GPD at 250 PSI
The control options that you can select from the second dropdown menu are:
- X = (Standard) Control (Default Selection)
- D = Auto Stop Input with 8’Cord
- E = External Pace
- G = Flow Switch only with 8’ Cord
- H = Flow Switch Unassembled
The voltage options that you can select from the third dropdown menu are:
- 1 = (Standard) 120 Volt USA plug (Default Selection)
- 2 = 240 No plug
- 3 = 240 Specified plug
- L = 120 Volt USA Plug with no Control Relay or Pigtail
WET END SELECTIONS
The head and fitting options that you can select from the fourth dropdown menu are:
- K = Kynar (Default Selection)
- S = 316SS*
- M = Kynar Head w/ SS MNPT Valves*
- D = Kynar Degassing
* M and S options must have P connection code
The seat and O-ring options that you can select from the fifth dropdown menu are:
- V = Viton (Default Selection)
- F = Teflon
- H = Hypalon
The connection options that you can select from the sixth dropdown menu are:
- 1 = 3/8” Tubing for 75-200 psi (Default Selection)
- 2 = 1/4” Tubing for 250 psi
- K = Kynar suct / disch tubing
- P = 1/4” MNPT
- Q = 1/4” MNPT disch / 1/4” FNPT suc
- R = 1/4” FNPT
- U = 3/8” Black UV resistant
- V = Clear flex 3/8” suct tubing
The ball check options that you can select from the seventh dropdown menu are:
- C = Ceramic (Default Selection)
- D = Ceramic (single on discharge)
- S = Stainless
OTHER OPTIONS
We are thinking that the following is getting a little too exotic and complicated for auto selection and are best addressed as a custom order. You can select and contact us for pricing on up to three of the following:
- 4 = Blue Housing
- 5 = Green Housing
- 6 = Conformal Coating
- F2 = Paddlewheel Flow Meter, Kynar construction
- F3 = Paddlewheel Flow Meter, input only, no sensor
- H = 3-Wire Input for Paddlewheel Sensor (5 VDC)
- N = 4-20 mA Output Isolated (requires power)
- P ON/OFF Power Switch
- R = Remove Stroke Adjust
- S = 3-Function Valve (25 lbs load, anti-siphon & check)
- 03 = Tank Mount ORP Probe
- 12 = Momentary Toggle Switch for WM Input
If you need further customization than what you see here, Contact Us.
Chemical Compatibility
When building the liquid end portion of a pump model it is critical that the materials selected are compatible with the product to be pumped. Listed below are some common chemicals and recommended liquid end codes. Example: Sodium Hypochlorite (chlorine) A130X1-KVCV.
Chemical | Code |
ACETIC ACID, 5-10% | KHC |
ALUMINUM SULFATE ‘alum’ | KHC |
AMINES, 0 - 35% | KFC |
AMINES, > 40% | SFS |
AMMONIA, 10% | KHC |
BROMINE | KFC |
CALCIUM HYPOCHLORITE | KVC |
DBNPA | KFC |
ETHYLENE GLYCOL | KFC |
FERRIC CHLORIDE | KFC |
FERRIC SULFATE | KFC |
GLUTARALDEHYDE | KFC |
HYDROCHLORIC ACID, 0 - 37% | KFC |
HYDROGEN PEROXIDE, 0 - 30% | KVC |
INHIBITING PHOSPHONATES | KFC |
ISOTHIAZOLINE | KFC |
NITRIC ACID, 0 - 20% | KVC |
PHOSPHORIC ACID, 0 - 100% | KFC |
POTASSIUM CHLORIDE | KFC |
SODIUM BI-CARBONATE ‘soda ash’ | KFC |
SODIUM BI-SULFATE | KFC |
SODIUM BI-SULFITE | KFC |
SODIUM BROMIDE | KFC |
SODIUM CARBONATE | KFC |
SODIUM HYDROXIDE, ‘caustic’, 0 - 50% | KHC |
SODIUM HYPOCHLORITE | KVC |
SODIUM NITRATE | KFC |
SODIUM SILICATE | KHC |
SODIUM SULFATE | KHC |
SODIUM SULFIDE | KHC |
SULFURIC ACID, 10 - 75% | KFC |
SULFURIC ACID, 95 - 100% | KFC |