K-1583 Drop Test, Phosphonate, Thorium nitrate/xylenol orange
FOR CURRENT DISCOUNTS, SEE TERMS OF SALE TAB (LEFT).
With few exceptions, you get free shipping on orders over $100.00, lower 48 States of the USA.
We accept Visa, MasterCard, American Express, Discover, and PayPal.
To Get Members Only Benefits, Click "Save Time On Your Next Visit" at Check Out.
Instant message me with your questions.
IF THIS PRODUCT IS NOT AVAILABLE FOR DIRECT PURCHASE, CLICK HERE TO CONTACT US FOR A QUOTATION
We have established a Reagent Pack for this test kit where you can purchase additional or replacement reagents. Click Here.
Taylor Technologies test kit K-1583 Drop Test, Phosphonate, Thorium nitrate/xylenol orange Method (uses pH test paper 1.8-3.8). 1 drop = 1 ppm ATMP (Aminotri (methylenephosphonic acid)) plus conversion factors for ATMP-related phosphonates.
To express phosphonate as: | Multiply drops by: |
Aminotri(methylenephosphonic acid) (ATMP) | 1.0 |
Aminotri(methylenephosphonic acid), pentasodium salt (Na5ATMP) | 1.3 |
1-Hydroxyethylidene-1,1-diphosphonic acid (HEDP) | 0.9 |
Hexamethylenediaminetetra(methylenephosphonic acid), hexapotassium salt (K6HDTMP) | 1.2 |
Diethylenetriaminepenta(methylenephosphonic acid) (DTPMP) | 1.45 |
Diethylenetriaminepenta(methylenephosphonic acid), pentasodium salt (Na5DTPMP) | 1.7 |
Taylor offers two drop-count titration tests for phosphonate (see chart). Both (ON SALE FOR 10% OFF) employ the thorium nitrate method, but one uses xylenol orange (XO) as the phosphonate indicator and the other uses chrome azurol S (CAS). They also differ in the pH indicator used, in the acid provided for adjusting pH, in the treatment blends that can be monitored, and in the drop equivalencies for a particular antiscalant. Specifically, the XO kit K-1583 is designed for use with ATMP, Na5ATMP, HEDP, K6HDTMP, DTPMP, and Na5DTPMP. The CAS kit K-1584 is appropriate for testing ATMP, Na5ATMP, HEDP, plus HPA and PBTC. With either, analysts are instructed to run a blank before testing the treated water.
It should be noted that fluoride will interfere in the K-1584 phosphonate test but the K-1583 contains a fluoride masking agent. Both tests are affected by the presence of iron, orthophosphate, and polyphosphate. If unusual test results cause you to doubt their validity, test for these interfering agents.
Component | Description | Quantity | ||
5051 | INS,DT,PHOSPHON,1PPM | 1 | ||
7040 | LABEL,CASE,DT/SC,8.5X2.5,VIVO | 1 | ||
7060 | CASE DTK RIBBED 11.5X5.25X2 | 1 | ||
8126 | KIMPAC 4.5 X 11 | 1 | ||
9198P | SAMPLE TUBE 5-25ML W/PURPLEDOT | 1 | ||
9315 | PH PAPER,1.8-3.8 | 1 | ||
R-0686P-C BUY THIS |
SULFURIC ACID N;2OZDB,PURP CAP | 1 | ||
R-0697-C | THIOSULFATE N/10; 2 OZ DB | 1 | ||
R-0802P-I | XO IND PDR; 10 GM V | 1 | ||
R-0803-C | PHOSPHONATE TTR SOL,2OZ DB | 1 | ||
R-0805-C | FLUORIDE MASKING AGENT; 2 OZDB | 1 |
To find Replacement Parts of this and other Taylor Technology test kits, Click Here.
To find Reagents for this and other Taylor Technology test kits, Click Here.
For the most accurate test results, it is advisable to replace ALL of your reagents annually. Some reagents can go bad and others can become contaminated with impurities or other reagents during use.
Prices for the Continental 48 states of the USA only. K1583 Taylor Test Kits